Sulky VISION 1 WPB Instrukcja Użytkownika Strona 55

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 57
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 54
55
Informations
Information
Informationen
Faults - Solutions
Faults Solutions
The unit does not lit up Check - unit/power supply connections
- fuses supply line
Flow rate test Check - calibration factor
Repeat the test in Static mode
Shutters open to maximum then to minimum Check - Tractor drive rate coefficient.
- spreading width
(24.00, beware of the decimal sign)
The unit lits up but the rams do not move Check - Fuses
Area counter reading incorrect Check - connection / machine
- working width
- drive rate
Flow rate Check - programmed flow rate
- fertiliser coefficient
- PDF rate = 540 RPM
- spreading width
- tractor drive rate
- shutter opening/closing performance
- ram travel
- peg marking
The drive rate is incorrect Check - connection on unit
- sensor magnet clearance
- magnet rotation
- sensor wire continuity
(100 ± 10)
- 100-m coefficient
Tonnage counter reading incorrect Check - connection / machine
- working width
- drive rate
- fertiliser coefficient
- shutter opening/closing
GB
Przeglądanie stron 54
1 2 ... 50 51 52 53 54 55 56 57

Komentarze do niniejszej Instrukcji

Brak uwag