Informations / Information / Informationen
1
4
G
B
Faults - Solutions
E
FA
ULTS
SO
LUTIONS
The unit does not lit up Check - unit/power supply connections
- fuses supply line
Flow rate test Check - calibration factor
Repeat the test in Static mode
Shutters open to maximum then to minimum Check - Tractor drive rate coefficient.
- spreading width
(24.00, beware of the decimal sign)
The unit lits up but the rams do not move Check - fuses
- the battery power supply
Area counter reading incorrect Check - connection / machine
- working width
- drive rate
Flow rate Check - programmed flow rate
- fertiliser coefficient
- PDF rate = 540 RPM
- spreading width
- tractor drive rate
- shutter opening/closing performance
- ram travel
- tramlining
The drive rate is incorrect Check - connection on unit
- sensor magnet clearance
- magnet rotation
- sensor wire continuity (100 ± 10)
- 100-m coefficient
The tonnage counter reading is incorrect Check - connection / machine
- working width
- drive rate
- fertiliser coefficient
- shutter opening/closing